Flex Automotive
Every Motor, Every Fault: Testing the Zone Controller

Every Motor, Every Fault:
Testing the Zone Controller

FLEX AUTOMOTIVE

Informationen anfordern

Überblick

Flex Automotive verifies the motor outputs of its new automotive zone-controller portfolio on Impedyme’s CHP-Serie Motor Emulator — with brushed and brushless DC motors emulated from approximately 1 A to 30 A and faults injected on demand.

Learn how software-defined motor models replace the collection of physical motors, harnesses, and mechanical fixtures a zone-controller portfolio would otherwise need — and turn startup, stall, regeneration, and fault cases into repeatable, automated regression tests.

−45 %

testing time

−40 %

validation time

+50 %

test coverage

+55 %

system safety

The Challenge

One controller family, many motors

01

Flex is one of the world’s leading manufacturing and technology partners. Its automotive business, Flex Automotive GmbH in Filderstadt, Germany, develops modular zone-controller platforms for software-defined vehicles. The platforms combine eFuses, high- and low-side switches, motor and actuator drivers, and in-vehicle networking into configurable, pre-validated building blocks.

02

Flex’s new zone-controller portfolio has to drive many low-current brushed and brushless DC motor loads. Conventional verification depends on physical motors, wiring harnesses and mechanical fixtures, and these differ from one motor type to the next. That makes it hard to reproduce the same conditions across controller variants and software releases, including current profiles, startup behavior, stall conditions, back EMF, regeneration and fault cases.

03

Flex needed a single, reusable verification environment that works for every motor output and product configuration. It had to provide programmable motor behavior across the full 1 A to 30 A range, synchronized with automated test sequences.

The Solution

An emulated motor for every output

 

Impedyme built a der Motor-Emulator Testbench on the CHP Series in a 19-inch, 42U liquid-cooled cabinet, sized for the controller’s 1 A to 30 A motor outputs. Real-time motor models run on the module’s Zynq UltraScale+ FPGA under IMPEDYME-RT. A bidirectional, four-quadrant interface means each controller output drives what it sees as a real machine, at real current.

In MotorSim Studio, engineers choose brushed or brushless DC motor models. They then set winding resistance and inductance, back EMF, inertia, friction and mechanical loading, along with speed and torque profiles and operating sequences. The motor behavior is fully controlled, so it repeats identically across revisions of the controller hardware, firmware and calibration.

A Fault Inject Unit, reached over Ethernet and controlled from PowerHIL Studio, applies fault cases on demand. Short-circuit cases include DC link, phase-to-phase, phase-to-ground and sensor lines, and open-circuit cases are also available. Engineers can test fault scenarios safely and reproduce them at any time, without damaging physical motors or wiring.

PowerHIL Studio sequences the test campaigns and enforces safety limits. FPGA Scope captures synchronized voltage, current, speed, position and status data. An optional environmental chamber (1000 L, 0–80 °C, 15–95 % RH) runs the same tests across a range of temperature and humidity conditions.

SoftwareRole in Flex’s zone-controller verification workflow
MotorSim StudioMotor-emulation control: brushed and brushless DC motor models on the FPGA; winding R and L, back EMF, inertia, friction, and mechanical-load profiles; parameter variation and LUT management.
PowerHIL StudioTestbench operation: cabinet-level control, signal routing, safety monitoring, automated regression sequencing, failure emulation, and Fault Inject Unit control.
IMPEDYME-RTLinux with Impedyme’s proprietary real-time kernel on every module; runs MATLAB/Simulink™ models on the Arm cores and FPGA (200 ns FPGA update); real-time monitoring, control, and parameter tuning from MATLAB.
FPGA ScopeReal-time FPGA-based capture of voltage, current, speed, position, and status with trigger-based precision — waveform evidence for every startup, stall, and fault case.
MLXPost-processing and analytics of streamed data in MATLAB — operating-point sweeps, efficiency and response metrics, pass/fail overlays, and automated test reports.

In Practice

Startup to stall, reversal to regeneration

Direct Connection

A zone-controller output connects directly to the Impedyme Motor Emulator. The emulator reproduces the selected brushed or bürstenloser Gleichstrommotor, from back EMF to inertia and load.

Full Operating Range

Engineers evaluate startup, acceleration, steady operation, reversal, braking and regeneration, all under controlled and repeatable conditions.

Protection and Faults

Engineers also test stall response, current limiting, open-load behavior and selected electrical faults. The controller’s own eFuses and protection logic respond to each case.

Automated Regression

Motor models are reusable, and currents sweep from 1 A to 30 A in software. The same automated sequence runs on every zone-controller variant and runs again after every hardware or software change

flex success story

Benefit (vs. previous workflow)Customer-reported impact
Reduced development time−30 %
Reduced testing time−45 %
Reduced validation time−40 %
Reduced testing costs−30 %
Improved engineering productivity+40 %
Improved test coverage+50 %
Improved system safety+55 %
Improved confidence before hardware deployment+50 %

The Results

The Impedyme Motor Emulator gives Flex one verification workflow for the whole zone-controller portfolio. Test engineers load reusable brushed or brushless motor models, sweep current and operating conditions from about 1 A to 30 A, automate regression sequences, and capture synchronized voltage, current, speed, position and status data. Bench reconfiguration drops, and results stay consistent across development teams and product variants.

Flex Automotive reported and approved the measured impact. Development time fell 30 %, testing time 45 %, validation time 40 % and testing costs 30 %. Engineering productivity rose 40 %, test coverage 50 %, system safety 55 % and confidence before hardware deployment 50 %. Repeated motor and fixture changes became software-defined configurations, which sped up verification. The automated tests are reusable, so they apply to every variant and run again after any hardware or software change.

The platform makes many cases repeatable across the 1 A to 30 A range: startup, stall, rapid load changes, reversal, regeneration, current limits, parameter variation and faults. These conditions are hard to reproduce precisely and safely with a collection of physical brushed and brushless motors.

Flex’s platform is built from pre-validated blocks, and the testbench verifies it the same way. Every output is proven with a modular, repeatable method by design.

The Impedyme Motor Emulator covers a low-current range of 1 A to 30 A and runs both brushed and brushless DC motor models on one platform. It makes dynamic cases such as startup, stall and regeneration fully repeatable. A built-in Fault Inject Unit applies short-circuit and open-circuit faults on demand.

The motor models run in real time on a Zynq UltraScale+ FPGA (quad-core Arm, 600K logic cells) at a 200 ns update rate. Module ratings run from 5 kW to 50 kW and scale up to 5 MW. An optional 1000 L environmental chamber extends testing to 0–80 °C and 15–95 % RH.

The Added Value

Flex chose Impedyme because its approach combines programmable real-time motor models with a bidirectional electrical interface sized for the required 1 A to 30 A range: one platform reproduces brushed and brushless motor behavior, changes motor and load parameters in software, and synchronizes measurements with automated test sequences — a reusable verification environment for multiple zone-controller outputs and product configurations.

The capabilities Flex values most — the 1 A to 30 A operating range, brushed and brushless DC motor emulation, zone-controller verification, startup and stall testing, dynamic mechanical loads, back EMF and regeneration, motor parameter variation, automated regression testing, and protection and fault testing — are exactly what this testbench delivers. And every module is a fault-isolating unit with layered protection — over-voltage, over-current, over-power, over-temperature, short-circuit and desaturation detection, device-level destruction monitoring, and soft start/stop — so a test that goes wrong stops the test, not the program.

FunctionConventional benchImpedyme testbench at Flex Automotive
Motor loadsOne physical motor and fixture per motor typeBrushed and brushless DC motors emulated on FPGA — variants as parameter sets
Current rangeDifferent motors to cover 1 A to 30 AOne emulator swept across the full range in software
Dynamic casesHard to reproduce startup, stall, regenerationScripted startup, stall, reversal, braking, and regenerative cases
FehlerabdeckungRisky, manual, often destructiveFault Inject Unit: scripted short-circuit, open-circuit, and sensor-line cases
RegressionBench rebuilt per variant and releaseAutomated sequences rerun after every hardware or software change
Environmental testingSeparate rig in the chamberSame testbench with the optional 0–80 °C / 15–95 % RH chamber

WHY IT WORKS

One Platform

Brushed and brushless DC motors emulated on one platform

Full Current Range

Full 1 A to 30 A range swept in software

Repeatable Dynamics

Startup, stall, reversal, braking, and regeneration — repeatable

Software-Defined Motors

Motor variants as parameter sets, not physical motors and fixtures

Fehlerinjektion

Fault Inject Unit: scripted short- and open-circuit cases

Reusable Regression

Automated regression reused across every variant and release

Native Simulink Workflow

Native MATLAB/Simulink™ workflow — no third-party HIL simulator

Comprehensive Protection

Comprehensive protection: OV/OC/OP/OT, short-circuit, desaturation

Testing zone controllers without the motors?

Impedyme builds motor-emulation testbenches that replace physical motors and fixtures with one reusable setup, from 1 A to 30 A on every output.

Produkte